5A 12V Overcurrent Protection – AC Current Detection Sensor Module

LC 5A Over-current protection Sensor module uses a current transformer to collect the AC signal to achieve the relay over-current signal output within 0-5A. Relay pull while over-current, relay released while not over-current

SKU: 79604

IBOTS's 10th Anniversary Sale

Hurry and get discounts on all Raspberry Products up to 20%

IBOTS1000

319.00

  • Pick up from the IBOTS Store

Free

  • Delivery Charges: Tamil Nadu

₹75 for parcels below 1 Kg and ₹100 for parcels weighing between 1 Kg to 2 Kg.

2-3 Days

₹75

  • Delivery Charges: Other South India

₹125 for parcels below 1 Kg and ₹175 for parcels weighing between 1 Kg to 2 Kg.

2-3 Days

₹125

  • Delivery Charges: North India

₹250 for parcels below 1 Kg and ₹325 for parcels weighing between 1 Kg to 2 Kg.

2-3 Days

₹250

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Rs. 99

  • Warranty 1 year
  • Free Returns Policy

Payment Methods:

1. Order the Product and Specify the Delivery Method

2. You Will Receive an Order Confirmation Message

3. Wait for Your Order to Arrive

4. Pick up Your Order at The Checkout Area

Description

LC 5A 12V Overcurrent Protection AC Current Detection Sensor Module uses a current transformer to collect the AC signal to achieve the relay over-current signal output within 0-5A. Relay pull while over-current, relay released while not over-current. Users can use the relay COM; NC, NO three ports to control the external circuit on and off, in order to achieve over-current protection.

Functions:

  1. Current detection resolution can change the parameter of resistance parameters;
  2. Output over-current switching signal output;
  3. The over-current signal setting critical point adjustable.
Using Instructions: 
By setting the potentiometer to set the overcurrent protection point, the clockwise adjustment reduces the detection current.
As bellows:
  1. Measured the wire through the current transformer, connect VCC and GND to the DC12V power supply;
  2. Adjust the potentiometer, when you hear the sound of the relay pull (can be measured with a multimeter COM and NO whether was turned on; is connected to the relay means activated), then reduce or cut off the current flowing  that through the tested wire; if the relay release at this time that over-current protection point has been identified (available to multimeter COM and NC measurement whether is connected; is connected to the relay means it release);
  3. When reduce or cut off the current flowing through the wire; the relay is not released, will still need to continue to adjust the potentiometer to find the over-current protection point.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.